Charging Technology

Charger termination voltage is a function of series count. It is not a preference.

Multiply the series count by 3.65 V and you have the charger. Sixteen cells terminate at 58.4 V, nineteen at 69.4 V, twenty-three at 84 V. Every JRP charger exists because a JRP architecture needs it.

Architecture and charger

Charger compatibility by pack architecture
ChargerArchitectureCompatible packsTypical charge time
58.4V / 6A 48V Series 48V / 30A ~5-6 h
58.4V / 10A 48V Series 48V / 45A, 48V / 60A ~5-7 h
69.4V / 6A 60V Series 60V / 24A, 60V / 30A ~4-6 h
69.4V / 10A 60V Series 60V / 45A ~5 h
84V / 6A 72V Series 72V / 30A ~5-6 h
84V / 10A 72V Series 72V / 45A ~5 h
The failure mode this prevents

A 69.4 V charger on a 48V pack pushes each of sixteen cells to about 4.3 V — far past the 3.65 V limit for LFP. The BMS will try to stop it, but a protection system is a last line of defence, not a substitute for using the right charger.